Closed-Loop Responsive Neurostimulation (RNS) for Refractory Epilepsy
Co-developed by Xuanwu Hospital (Prof. Guoguang Zhao) and Tsinghua University, the Closed-Loop Responsive Neurostimulation (RNS) system transforms intractable epilepsy care for patients whose foci overlap critical motor or language speech areas. Unlike conventional continuous DBS, the RNS neurostimulator monitors intracranial electrocorticograms (ECoG) 24/7. When automated algorithms detect incipient epileptiform spikes, it delivers targeted micro-bursts within milliseconds to abort the seizure before clinical manifestations emerge.
Sur cette page
Closed-Loop Responsive Neurostimulation · RNS Smart Interception
国家药监局 NMPA 创新医疗器械特别审查 / 临床研究注册 (NCT04561284) · Class III Innovative Neuromodulation Device / AI-Driven Epilepsy BreakthroughCo-developed by Xuanwu Hospital (Prof. Guoguang Zhao) and Tsinghua University, the Closed-Loop Responsive Neurostimulation (RNS) system transforms intractable epilepsy care for patients whose foci overlap critical motor or language speech areas. Unlike conventional continuous DBS, the RNS neurostimulator monitors intracranial electrocorticograms (ECoG) 24/7. When automated algorithms detect incipient epileptiform spikes, it delivers targeted micro-bursts within milliseconds to abort the seizure before clinical manifestations emerge.
Median Seizure Frequency Reduction
75.0% (长期随访达 82.0%)
Control: 14.2%
Evidence Level
ILAE and AAN Guidelines Class I Level A Recommendation
Xuanwu Hospital (Capital Medical University) & Tsinghua University
Treatment Course
3-5 Days MDT Workup
Periodic clinical follow-up with regimen optimization
Global Advantage
Direct Billing Available
Mechanism of Action (MOA)
24/7 Cortical ECoG Sensing + AI Seizure Pattern Detection + Subsecond Closed-Loop Abort
1Craniectomy-Flushed Flush Implantation: Ultra-thin stimulator integrates flush with the cranium under the scalp, invisible and cosmetically pristine.
2Stereotactic Robotic Multi-Target Placement: Depth or strip leads placed precisely at bilateral seizure onsets (e.g., mesial temporal, motor cortex).
3Embedded AI Spike Recognition: Real-time algorithm detects electrographic onset within milliseconds based on line-length and frequency shifts.
4Subsecond Disruption & Telemetry: Delivers targeted charge-balanced pulses aborting seizure spread; data wirelessly syncs to clinical databases.
Patient Profile & Indications
Quantified entry criteria and stages for foreign referral
Medically refractory focal onset epilepsy failing >=3 appropriate antiepileptic drug regimens.
Epileptogenic foci localized to bilateral brain regions (e.g., bilateral mesial temporal lobe onset) where resection is contraindicated.
Seizure onset located in eloquent cortex (Broca's speech area, primary motor cortex) where resection would induce irreversible deficits.
Patients with persistent disabling seizures despite prior surgical resection or vagus nerve stimulation.
Strict Exclusion Red Lines
- ✕Generalized epilepsy syndromes (idiopathic generalized epilepsy with absence or generalized spikes).
- ✕Diffuse or multifocal epileptogenic zones (>2 independent non-contiguous foci).
- ✕Severe psychiatric disorders, active psychosis, or progressive neurodegenerative disease.
- ✕Requirement for repetitive high-power full-body MRI examinations.
Clinical Trial Data & Real-World Outcomes
China National Multicenter Closed-Loop RNS Prospective Study
Median Seizure Frequency Reduction
75.0% (长期随访达 82.0%)
Disease Control (DCR)
91.5%
Evidence Grade
ILAE and AAN Guidelines Class I Level A Recommendation
Safety Profile: Memory and cognitive scores preserved or improved over long-term follow-up; zero permanent resection-related neurological deficits; infection rate <2.1%.
Official Regulatory Registries & Authoritative Sources
Direct verification links to NMPA, ClinicalTrials.gov, PubMed and CSCO/FDA registries
Neurology Landmark
Neurology: Nine-Year Prospective Safety and Efficacy of the RNS System
NMPA Priority
NMPA Innovative Medical Device Special Review
Global Approved Competitor Benchmark
Head-to-head comparison with US, EU, and Japanese approved equivalents
| Technique / Device / Brand | Developer | Mechanism / Platform | Clinical Indications | Approval & Region | Relative Cost |
|---|---|---|---|---|---|
| Closed-Loop Responsive Neurostimulation (RNS)Selected | Xuanwu Hospital / Tsinghua University | Cranially Implanted Neurostimulator & Intracranial Leads | Bilateral Foci · Eloquent Cortex Refractory Focal Epilepsy | China (NMPA Priority Innovation Channel)2023 | ~1/6 to 1/8 of US commercial charges |
Benchmark Hospital Centers
Pioneer institute in closed-loop responsive neurostimulation with world-class robotic stereotactic surgical expertise.
Xuanwu Hospital, Capital Medical University
Functional Neurosurgery & Comprehensive Epilepsy Center
Prof. Guoguang Zhao & Prof. Yongzhi Shan
Collaborating with Tsinghua Brain-Computer Interface Lab, leading cutting-edge neuromodulation algorithm optimization.
Tsinghua University Yuquan Hospital
Epilepsy Center & Clinical Electrophysiology
Prof. Wenjing Zhou
Premier South China hub providing comprehensive video-EEG evaluation and cloud-based tele-programming.
Foshan Chancheng Hospital (FIMC International Medical Center)
Functional Neurosurgery & International Medical Center
FIMC Neuromodulation Team
Required Medical Records:
•Continuous 24-72 hour long-term video-EEG (VEEG) recording ictal onsets and interictal spikes.
•High-resolution 3.0T brain MRI epilepsy protocol (thin-slice coronal T2/FLAIR assessing hippocampal anatomy).
•Prior SEEG intracranial monitoring reports detailing specific contact points of seizure initiation, if available.
•Comprehensive 12-month medication log with daily dosages, blood drug levels, and seizure diary.
Comment nous coordonnons
Remarque importante
Cette page fournit des informations générales et décrit la portée de la coordination ; ce n'est pas un avis médical. L'adéquation, les bénéfices attendus et les risques doivent être expliqués par l'hôpital d'accueil après évaluation complète.